Verify the function of the air outlet assembly in the use process, mainly including air outlet durability, air outlet operation force, air outlet blade abuse and other tests.
Test Item | Test Item |
Operating force test | Assemble solidity of air vent |
Durability test of air vent | Vibration test of air vent |
Misuse test of air vent | Air leakage test of air vent |
Case sharing:
Air outlet durability test EP 84 126.12 (2018-04) introduces that 13500lc cycle is completed in the following environment to verify the durability of air outlet assembly in the whole life cycle:
(1)10000LC at RT
(2)1000LC at 80℃
(3)1000LC at -25℃
(4)1500LC at 55℃/95% R.H.
Meet the test standards
of Volkswagen and Audi, replace the traditional electric cylinder and cylinder
equipment by robot detection, make up for the shortcomings of the traditional
equipment, and can be tested in the environment of - 30 ℃
to 90 ℃.